Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can utilize within this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live squander. Prohibit any volatile and radiation substance, liquid waste and gas waste. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time and time for feeding waste. Actual combustion time daily is about 16 hours. The life of incinerator between 5-10 year according to use.
Generally, we proposition little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed at the hospital, that's mean you need one incinerator capacity around 400kgs each day, change to capacity per hour is around 30-40 kgs per hour. According the operation time daily, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We supply all documents and incinerators easy to installation and operation. Client can send people come to our factory to find out installation and operation. Generally, we don’t send engineer to local site if not request. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control instance. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One individual can service 02 device incinerators. China animal cremation, china incinerator supplier, cloverincinerator, garden incinerator, hog incinerator, infectious waste pyrolysis machine china, The team must have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know risk of medical waste to protect worker self with essential protection element.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |