Additional Info.
Product Description
Q: What’s kind of waste can utilize in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live squander. Prohibit any volatile and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding waste. Burning incenrator manufactuer, burning medical waste, burning waste chamber, purchase a portable crematorium, purchase a small incinerator, purchase animal cremation systems, Real combustion time per day is about 16 hours. The life of incinerator between 5-10 year based on use.
Generally, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, that's mean you need 1 incinerator capacity around 400kgs each day, change to power per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We supply all documents and incinerators simple to setup and operation. Customer can send people come to our factory to find out operation and installation. Generally, We do not send engineer to local site or even ask. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, use situation.
One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know risk of medical waste to safeguard worker self with essential protection component.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
Oil Tank(Liters) | 50 | 100 | 100 | 150 |
Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
Chimney (M) | 5 | 5 | 5 | 5 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |