Product Description
Technology Respond(FAQ)
Q: What is kind of waste can use in this equipment? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid waste and gas waste. GB18484-2001. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time daily is around 16 hours. The lifetime of incinerator between 5-10 year based on use.
Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed at the hospital, that's mean you need 1 incinerator capacity around 400kgs per day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time daily, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We supply all documents and incinerators easy to setup and operation. Customer can send people come to our factory to find out operation and installation. Diesel oil fired medical waste incenerator, dual chamber incinerator, ecological incinerator, encenerator, farm incinerator, Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control manner is common control instance. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One individual can service 02 device incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know risk of medical waste to safeguard worker self with necessary protection element.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |