| Parameter | Compliance | 
| Type of Waste | To treat medical waste, categories A,B,C,D,E | 
| Type of Incinerator | Pyrolytic | 
| Nominal Burn rate | 50 t0 60 kg/ hr at 3500Kcal/Kg | 
| Loading | Manual, Batch Load | 
| De Ashing | Automatic or Manual batch de ashing | 
| The incinerator must avoid the release of black smoke and fine dust during the loading | |
| Primary chamber capacity | 2-3 m³ | 
| The insulation of the combustion chamber should be composed of refractory bricks, having a higher content of aluminium and insulates, | |
| The plate of combustion in carborundum avoiding the fixing of glass and slags | |
| Hours of operation /Day | >10 hrs | 
| Max Operating Temperatures | 1400 °C | 
| Normal Operating Temperatures(Primary) | >850 °C | 
| Operating Temperature(Secondary) | >1100 °C | 
| It should have digital temperatures regulator( Temperatures regulator in digital watch) | |
| Carbon content of ashes | <2% | 
| The installation should be completely free from visible smoke as well as offensive odours | |
| Residence time in second chamber | 2 second minimum | 
| The internal diameter of the Chimney | :Ø 400 | 
| Height of stack | >8m | 
| Burner operation | Automatic On/Off | 
| Fuel | Diesel | 
| Fuel consumption at raed capacity | >7kg waste /ltr | 
| Electricity consumption | <2kW at rated capacity | 
| Operating Voltage | 220 – 240V AC 50Hz | 
| Spare parts | Supply for 1 year quoted as option | 
| Consumables | Supply for 1 year of operation to be mentioned as option | 
| Warranty | Parts and service support: 1 year minimum post comissioning | 
| Service support | <72 hours | 
| Emission standard Compliance | BS3316 or equivqlent standard | 
| Process filtering system | Scruber to be mentioned as option | 
| CE Manufacturing Compliance | BS EN 746-2-1997 | 
| Design Specification | Type A,B,C,D,and E of medical waste | 
| Installation and Comissioning | Included in condition of supply | 
| Training in preventive and curative maintenance and use of the incinerator | Operator training inclusive in offer | 
| Capacity to treat Plastic | Not less than 40% by weight | 
TECHNICAL DEMANDS: PYROLYTIC BURNER
 
		