Design |
|
CA50 |
Picture |
|
|
Waste Therapy |
|
Medical Waste Incineration Treatment |
Feed Capacity |
|
Typical 100 kgs per feeding |
Burning Rate |
|
Average 50 kgs per hr |
Burning Time per Feed |
|
Average 2 hr |
Control Setting |
|
PLC( Programmable Logic Controller Burner) |
Voltage |
|
220V |
Power |
|
1.0 Kw |
Gas |
|
Diesel oil |
Burner |
|
Italy Burner |
Feed Mode |
|
Guidebook |
Temperature Monitor |
|
Digital Screen |
Gas use (Oil) |
|
Ordinary 16.9 Kgs/Hour |
Inner Measurements |
|
100x80x70cm (Key Chamber) |
External Dimensions |
|
230 x 130 x 155cm (text) |
Waste combustion chamber |
|
560Liters |
Message Combustion Chamber |
|
280Liters |
Oil Tank Capacity |
|
200 Litres |
Door Opening |
|
70 x 50cm |
Chimney |
|
5.0 M |
Gross Weight |
|
4500kgs |
Chamber Product |
|
Firebrick, Refractory Concrete |
Max. Warmth Value |
|
166,000 Kcal/Hr. |
|
|
Procedure Technical Specifications |
Solid Chamber temperature |
|
8000C -10000 C |
Gas Chamber temperature degree |
|
10000C -12000 C |
Chamber Anti-Rate |
|
17500C |
Residency time |
|
2.0 Sec. |
Burning efficiency |
|
> 98 percent |
Waste Lower Calorific Power |
3000Kcal